| DATA BASE PROJECT List of process machinery to serve Miscellaneous manufacturing paper - 1 ^ phase m³ / h 66,600 Miscellaneous manufacturing paper - 2 ^ phase m³ / h 66,600 Miscellaneous manufacturing paper - 3 ^ phase m³ / h 66,600 TOTAL m³ / h 200.000
Plant data Multi Waste® Type of plant Multi Waste® 75 MW Plant description Number of treatment units No. 3 Amount of air treated gpm 225,000 Maximum consumption of compressed air m³ / h 0.5 Installed electrical power (without vent. Centr.) 34.8 KW Electrical input axis KW 27.84 | RESULTS OBTAINED The multi Waste® 75 achieves a concentration of dust filter downstream of less than 8.0 mg/m3. Minor amounts of dust can only be obtained by adding a second stage of filtration.
SUPPLY LIST Plant Multi Waste® Collection materials Thickener compactor with net fiber filter N ° 3 Fan transport fibers to thicken N ° 3 Fan transport fiber filter N ° 3 Filtration Automatic filtration module Multi Waste® No. 3 Form afonizzazione N ° 3 Form mixture with shutters Ric / Esp N ° 3 STRUCTURE EXPORT PACK Structure in panels 4 x 4 x H4 N ° 3 Port for inspection N ° 3 |